Unicook
Over 300,000 people cooking safely!

Meet Part B of Building Regulations with Airis Stove Guard

Airis is a fire safety device that prevents fires in the kitchen, making it ideal for many types of schemes from studio apartments to student accommodation and extra care. Airis helps meet Part B1 Section 2 of fire safety building regulations.

  • Helps meet Part B1 Section 2 of fire safety building regulations
  • Prevents fires and toxic smoke
  • Dramatically reduces fire alarm activations
  • Cuts the power to the stove, only in a dangerous situation
  • Cuts fire risk by almost 50%
Play Airis building compliance video

"Our installation team have found this product very easy to programme… Our clients feel more confident with the product and have said they don't notice that it's there."

David Aitken, Electrical Installer

Fire Safety for New Builds and Retrofits

Avoid fire lobbies

Airis allows for better designs with fewer constraints while helping meet Part B1 Section 2 of building regulations.

Wireless building management

Airis Sense Wi-Fi allows for wireless building management functions across an entire development.

Leak detection

Airis can detect water leaks in real-time, allowing for intervention at the earliest opportunity.

Airis stove guard prevents fires intelligently

Airis uses a unique patented temperature measurement technique to accurately measure the temperature of pans on a hob.

Measuring the temperature of the pan is difficult because different materials radiate differently. In fact, when a simple infrared thermometer is used, a stainless steel pan at 100°C might be read as 50°C. Airis is the only device that overcomes this problem.

Airis Sense Multisensor and PCU components

If you have questions, we're here to help

We can call you back, or you can contact us by phone on 0208 798 3462 or click on "Contact Us" to send us a message.

5-star rating

Rated 5 stars by our customers

Unicook certifications

What is Airis stove guard?

Airis is a fire safety device that helps meet Part B of building regulations and goes beyond the current standards for BS EN 50615 and fire safety. Its AI-derived algorithms can analyse cooking fumes, human presence, real-time power use and more.

Airis comprises two components — the Multisensor and the PCU.

Airis Multisensor

The Airis Multisensor fits on the wall behind the stove or on the extraction hood above it.

The Multisensor monitors and senses many aspects of the cooking activity and the environment at once.

Airis PCU

The Airis PCU monitors the power used by the cooker and, when instructed by the Multisensor, disconnects the power to prevent a fire or smoke.

The PCU also monitors the power being consumed over time. 35A and 50A models are available.

Fire safety to help meet Building Regulations — without ongoing maintenance costs

Suitable for all electric hobs

Airis stove guard can be used on any hob up to 90cm wide powered by electricity, including induction.

Long battery life

The Airis Multisensor has a battery life of 3 to 7 years. The AA batteries are easily changed.

Certified BS EN 50615

Airis fulfils and goes far beyond the requirements of the BS EN 50615 standard, and helps meet certain building regulations.

No maintenance

Airis is simple to install and no servicing is required, with no ongoing maintenance costs for building owners.

Looking for More Details?

My mum lives alone since my Dad passed away a couple of years ago and I was worried about her cooking… Now she wouldn't be without it as over Christmas the phone rang and she forgot she was cooking. She said when she went back to the kitchen, cooking had stopped as the food she was frying started to burn and the Airis cut the power.
— Glenn Swanton

Frequently Asked Questions Relating To Airis Products

Can't find an answer to your question? View all FAQs

Does Airis help meet Part B of building regulations? +

Yes. Airis is a fire safety device that meets and exceeds BS EN 50615 and helps meet Part B1 Section 2 of fire safety building regulations.

Does Airis work with all types of electric hob? +

Yes. Airis works with all hobs/stoves powered by electricity, including induction, ceramic/halogen, and older 'iron ring' style hobs.

What about kitchen islands? +

For kitchen islands, a ceiling-mounted version of Airis is available called the Airis-C. Note that this model doesn't have Wi-Fi capability.

Can Airis be used on gas hobs? +

No. Airis is only for electric hobs (all types).

Are there different versions of Airis? +

Yes, but ALL versions of Airis prevent fire and most smoke.

How long is the warranty on Airis products? +

All Airis products come with a 2-year manufacturer's warranty. Please refer to the user manual on our Support page for further details.

How long does delivery take? +

Your order should arrive in 7 working days or less.

If you have questions, we're here to help

We can call you back, or you can contact us by phone on 0208 798 3462 or click on "Contact Us" to send us a message.

5-star rating

Rated 5 stars by our customers

Unicook certifications